Maximum thermal exchange and precise heat control with increased safety
This system is the ideal solution for heating gaseous, liquid or two-phase fluid at a specific flow rate.
Cast-in heaters consists of a cylindrical cast aluminium block which is heated.
The fluid to be heated circulates through an helical coil which is embedded in the cast aluminium block. The heat is precisely and efficiently transferred to the gas or liquid.
To minimise heat losses, the aluminium block is thermally insulated and protected by a casing.
As the system is highly flexible, the heater can be connected in series or in parallel, according to power requirements.
Regulation and control
A temperature probe is fitted as standard to monitor and control the skin temperature of the heating elements.
Other temperature probes are available as optional extras (for the aluminium block or at the heater inlet and outlet).
A control cabinet is used to control the heater.
The entire system is available in an explosion-proof version for the ATEX T1 (450°C) to T6 (85°C) environment or for other “safe” environment applications.
A compact alternative Cast-in circulation heaters are excellent alternatives to conventional heaters consisting of an immersion heater mounted in a body.
They save space, have lower costs and are very competitive for high pressure applications.
System maintenance is also considerably reduced.
CETAL heaters are available for specific flow rates and process power requirements.
The range starts at 1.5 kW to 32 kW as standard and is available with either a 230 V single-phase, 400 V three-phase to 690 V three-phase power supply.
CETAL manufactures its own heating elements which are the key components (active parts) of all electric heating systems. The design is defined according to customer specifications.
The watt density, tube diameter and the tube sheath are chosen to optimize the reliability and robustness (corrosion, temperature) of CETAL equipments.
Type |
Power |
Max. |
Max. flow rate |
Max. |
Distance |
Ext. Ø |
Tube |
Width* |
Length* |
Height* |
Weight (kg) |
Cast-in circulation heater 01-xx kW |
1.5/3 |
10 |
100 |
0.2 |
90 |
6.35 |
1.24 |
240 |
470 |
190 |
30 |
Cast-in circulation heater 02-xx kW |
1.5/3 |
25 |
250 |
0.5 |
8 |
1 |
30 |
||||
Cast-in circulation heater 03-xx kW |
1.5/3/6 |
40 |
400 |
1 |
10 |
1 |
30 |
||||
Cast-in circulation heater 04-xx kW |
1.5/3/6 |
55 |
560 |
1.5 |
140 |
13.7 |
2.24 |
310 |
500 |
220 |
45 |
Cast-in circulation heater 05-xx kW |
3/6/9/12 |
120 |
1300 |
3 |
17.2 |
1.6 |
45 |
||||
Cast-in circulation heater 06-xx kW |
3/6/9/12/24 |
180 |
1900 |
4 |
250 |
21.3 |
2.11 |
430 |
520 |
275 |
90 |
Cast-in circulation heater 07-xx kW |
6/9/12/24 |
320 |
3300 |
7 |
26.7 |
2.11 |
95 |
||||
Cast-in circulation heater 08-xx kW |
6/9/12/24 |
540 |
5500 |
11 |
33.4 |
2.77 |
110 |
||||
Cast-in circulation heater 09-xx kW |
6/9/12/24/32 |
850 |
8600 |
19 |
340 |
42.2 |
2.77 |
540 |
550 |
320 |
240 |
Cast-in circulation heater 10-xx kW |
9/12/24/32 |
1150 |
12000 |
26 |
390 |
48.3 |
2.77 |
590 |
550 |
345 |
250 |
* subject to change
Electric heating controls for industrial processes must be designed for the characteristics of the fluid to be heated and also take into account the process specifications.
CETAL offers an economical range of power supply and control cabinets. They are specially designed to control cast-in circulation heaters.
The design of the pre-configured cabinets allows for simplified quick installation and safe commissioning. They are supplied in the form of IP54 sealed metal boxes with a small, space-saving footprint.
Depending on the process, two methods of regulation are available: the standard version with a contactor controlled by a PID controller or, optionally, with a static contactor (thyristor).
The front panel controls are easy to use: